Książka 4D Image Verification Christian Schaller

4D Image Verification

Język: Angielski
Oprawa: Miękka
Wydawca: Grin Publishing
Dostępność: Dostępna u dostawcy
Wysyłamy za 9-15 dni
255.44
Diploma Thesis from the year 2007 in the subject Computer Science - Applied, grade: 1,0, Friedrich-A...

Informacje o książce

Język
Angielski
Oprawa
Książka - Miękka
Data wydania
2009
strony
100
EAN
9783640333271
ISBN
3640333276
Enbook ID
01621036
Wydawca
Waga
141
Wymiary
148 x 210 x 8

Pełny opis

Diploma Thesis from the year 2007 in the subject Computer Science - Applied, grade: 1,0, Friedrich-Alexander University Erlangen-Nuremberg (Lehrstuhl für Mustererkennung), 66 entries in the bibliography, language: English, abstract: Far reaching developments and technical advances took place within the field of radiotherapy in the last years. Radiotherapy within the chest and abdomen area is especially important in the field of radiotherapy. Within this regions, organ and tumor positions are significantly affected by patient respiration. The tumor motion, caused due to respiration is compensated by extending the treated area. This extension covers all possible positions of the tumor and therefore also includes healthy tissue.Several clinical studies provide evidence of a survival advantage for higher dose levels. To spare a maximum of healthy tissue physicians use gated radiotherapy . Common recent approaches for gated radiotherapy are based on the observation of a surrogate. This either can be an implanted fiducial marker or an external signal, which is trying to capture the patients respiration.Within this thesis principles and methods of gated radiotherapy are described. Additionally an overview of recent patents and products related to radiotherapy are presented and advantages and disadvantages of both common approaches are discussed. This discussion leads to a new developed method, which is introduced. The method joins advantages of both known methods but disregards their disadvantages. The developed algorithm is using image guided methods and methods of medical image processing. A mapping between a 4D-CT planning volume and a most recent acquired fluoroscopic sequence of the same patient is calculated before treatment. Using this mapping and an external breathing signal the physician can define gating intervals and treat the patient in certain breathing phases.The developed algorithm is included in an existing prototype developed by Siemens Corporate Research (SCR) in Princeton, NJ, USA. Using this prototype, the application of the method is shown. Furthermore another prototype to acquire respiration synchronized fluoroscopic sequences is developed. Both applications are introduced within this thesis.

Możesz być zainteresowany

423.79

Obligation

Liu Jia
612.01

Is This My Love?

Gertrude E. Bridgeman Finney
87.38

Le Barbier de Séville, Ed. by A. Dobson

Pierre Augustin Caron De Beaumarchais
79.59
138.04

New Testament

G. H. Lee
83.19

Prelude to Galileo

William A. Wallace
212.57
19.67

Olympic Dream

Reinhard Kleist
65.95

Klienci, którzy kupili tę książkę, kupili również

71.89
61.56

Rote Bete

Franziska von Au
37.60

Libera tus sombras

Kelly Bramblett
54.94